TSXSCY21601C
Product ID:34782
Updated: 2026/4/3

Key Features
- 1Efficiently manage communication for up to 28 connected devices. 2、Seamlessly integrate with the Modicon Premium automation platform. 3、Utilize Unity Pro software for advanced programming and control. 4、Handle multiple industrial protocols for versatile application support. 5、Ensure reliable data transmission with robust error-checking mechanisms.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | Modicon Premium Automation platform | Product or Component Type | Communication module |
| Software Designation | Unity Pro | Structure type | Heterogeneous industrial bus |
| Product Compatibility | Premium<br />Atrium | Method of access | Master/slave type |
| Integrated connection type | 1 serial link 1 SUB-D 25<br />1 slot for PCMCIA type III card | communication port protocol | Multiprotocol |
| Communication port support | RS485 isolated | Mode of Transmission | Asynchronous in baseband |
| Transmission frame | RTU/ASCII | Transmission Rate | 1.2...19.2 kbit/s |
| Transmission support medium | 2 twisted shielded pairs cable | Number of devices | 28 |
| Number of addresses | 0…97 | Bus length | 0.0000000000…4265.09 ft (0…1300 m) Modbus |
| Maximum tap links length | 49.2 ft (15 m) | Requests | 120 words per request<br />1920 bits per request |
| Control parameter | One CRC 16 on each frame | Monitoring function | Event counters<br />Diagnostic counters |
| Modbus funtions available | Event connection Modbus master 0C<br />Event connection Modbus slave 0C<br />Event counter Modbus master 0B<br />Event counter Modbus slave 0B<br />Identification Modbus slave 11<br />Slave identification Modbus master 11<br />Write n output bits Modbus slave 0F<br />Write n output words Modbus slave 10<br />Diagnostic Modbus master 08<br />Diagnostic Modbus slave 08<br />Exceptional read status Modbus master 07<br />Exceptional read status Modbus slave 07<br />Read input words Modbus master 04<br />Read n input words Modbus slave 04<br />Write 1 bits or n bits Modbus master 05<br />Write 1 input word Modbus slave 06<br />Write 1 output bit Modbus slave 05<br />Write 1 word or n word Modbus master 06 | Local signalling | for communication (CH0) 1 LED<br /> for internal fault, module failure (ERR) 1 LED<br /> for module operating (RUN) 1 LED |
| Current consumption | 350 mA 5 V DC | Module format | Standard |
| Net Weight | 0.79 lb(US) (0.36 kg) | Ambient Air Temperature for Operation | 32…140 °F (0…60 °C) |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) | Relative Humidity | 5…95 % without condensation |
| Operating altitude | <= 6561.68 ft (2000 m) |
Specifications may be subject to change without notice