XB6ECW3J2P

Product ID:36286
Updated: 2026/4/6
schneider XB6ECW3J2P

Key Features

  • 1Ensure high reliability with robust industrial construction. 2、Simplify installation for easy system integration. 3、Configure circuits flexibly with 2 NO/NC contacts. 4、Guarantee durability via IPB spring return mechanism. 5、Save panel space with Ø16 compact flush design.
Product Details
XB6ECW3J2P
schneider

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
Harmony XB6E
Product or Component Type
Illuminated monolithic push-button
Device short name
XB6E
Bezel material
Plastic
Mounting diameter
0.6 in (16 mm)
Sale per indivisible quantity
5
Shape of signaling unit head
Square
Type of operator
spring return
Operator profile
Green flush
Contacts type and composition
2 C/O
Contact operation
Snap action
Connections - terminals
Insulated faston 2.8 x 0.5 mm<br />Solder terminal <= 0.75 mm² AWG 19<br />Fast connector socket
Contacts material
Gold-flashed silver
Light source
Integral LED
[Us] rated supply voltage
12 V DC polarised
Net Weight
0.013 lb(US) (0.006 kg)
Operating position
Any position
marking
CE
Mechanical durability
1000000 cycles
Contact resistance
50 mOhm 1/6 V
Short-circuit protection
2 A cartridge fuse gG
[Ith] conventional free air thermal current
3 A fast connector socket)<br />5 A
[Ie] rated operational current
1.5 A 120 V, AC-12 IEC 60947-5-1<br />1 A 240 V, AC-12 IEC 60947-5-1<br />1 A 24 V, DC-12 IEC 60947-5-1<br />0.7 A 24 V, DC-13 IEC 60947-5-1<br />0.2 A 125 V, DC-12 IEC 60947-5-1<br />0.15 A 125 V, DC-13 IEC 60947-5-1
Electrical durability
100000 cycles, AC, 0.7 A 220 V IEC 60947-5-1 appendix C
Signalling type
Steady
current consumption
10 mA
Service life
30000 h
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
14…131 °F (-10…55 °C)
IP degree of protection
IP65 IEC 60529
Standards
CSA C22.2 No 14<br />UL 508<br />IEC 60947-5-1<br />JIS C 4520<br />IEC 60947-1<br />JIS C 852
Product Certifications
CCC<br />cURus
Vibration resistance
1 mm 10…55 Hz)IEC 60068-2-6
Shock resistance
10 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice