schneider XB6EDA51P

Key Features

  • 1Achieve IP65 protection against dust and water ingress. 2、Simplify installation with a clip-together component system. 3、Utilize a versatile rectangular design for various control panels. 4、Integrate a compact Ø16mm body into space-limited installations. 5、Ensure reliable operation with a high-quality, long-life construction.
Product Details
XB6EDA51P
schneider

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
Harmony XB6E
Product or Component Type
Monolithic push-button
Device short name
XB6E
Bezel material
Plastic
Mounting diameter
0.6 in (16 mm)
Sale per indivisible quantity
5
Shape of signaling unit head
Rectangular
Type of operator
spring return
Operator profile
Yellow flush
Contacts type and composition
1 C/O
Contact operation
Snap action
Connections - terminals
Insulated faston 2.8 x 0.5 mm<br />Solder terminal <= 0.75 mm² AWG 19<br />Fast connector socket
Contacts material
Gold-flashed silver
Net Weight
0.013 lb(US) (0.006 kg)
Overvoltage category
II IEC 60536
Operating position
Any position
marking
CE
Mechanical durability
1000000 cycles
Tightening torque
5.3…8.9 lbf.in (0.6…1 N.m)
Contact resistance
50 mOhm 1/6 V
Short-circuit protection
2 A cartridge fuse gG
[Ith] conventional free air thermal current
3 A fast connector socket)<br />5 A
[Ie] rated operational current
1.5 A 120 V, AC-12 IEC 60947-5-1<br />1 A 240 V, AC-12 IEC 60947-5-1<br />0.7 A 240 V, AC-13 IEC 60947-5-1<br />1 A 120 V, AC-13 IEC 60947-5-1<br />1 A 24 V, DC-12 IEC 60947-5-1<br />0.7 A 24 V, DC-13 IEC 60947-5-1<br />0.2 A 125 V, DC-12 IEC 60947-5-1<br />0.15 A 125 V, DC-13 IEC 60947-5-1
Electrical durability
100000 cycles, AC, 0.7 A 220 V IEC 60947-5-1 appendix C
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
14…131 °F (-10…55 °C)
IP degree of protection
IP65 IEC 60529
Standards
UL 508<br />JIS C 4520<br />IEC 60947-1<br />IEC 60947-5-1<br />CSA C22.2 No 14<br />JIS C 852
Product Certifications
CCC<br />cURus
Vibration resistance
1 mm 10…55 Hz)IEC 60068-2-6
Shock resistance
10 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice