XB6EDF4J2P
Product ID:36449
Updated: 2026/4/5

Key Features
- 1Achieve IP65 protection against dust and water ingress. 2、Utilize bright red LED illumination for clear status indication. 3、Configure versatile circuits with the DPDT switch mechanism. 4、Integrate seamlessly using the compact flush actuator design. 5、Ensure compliance with international CE and RoHS standards.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | Harmony XB6E | Product or Component Type | Illuminated monolithic push-button |
| Device short name | XB6E | Bezel material | Plastic |
| Mounting diameter | 0.6 in (16 mm) | Sale per indivisible quantity | 5 |
| Shape of signaling unit head | Rectangular | Type of operator | latching |
| Operator profile | Red flush | Contacts type and composition | 2 C/O |
| Contact operation | Snap action | Connections - terminals | Faston connectors 2.8 x 0.5 mm<br />Soldered connectors |
| Contacts material | Gold-flashed silver | Light source | Integral LED |
| [Us] rated supply voltage | 12 V DC polarised | Height | 0.7 in (18 mm) |
| Width | 0.9 in (24 mm) | Depth | 1.6 in (40 mm) |
| Terminals description ISO n°1 | (23-24-21-22)OF<br />(13-14-11-12)OF | Net Weight | 0.013 lb(US) (0.006 kg) |
| Overvoltage category | II IEC 60536 | Operating position | Any position |
| marking | CE | Operating force | 1.3 N C/O changing electrical state |
| Mechanical durability | 250000 cycles | Short-circuit protection | 3 A cartridge fuse gG |
| [Ith] conventional free air thermal current | 3 A | [Ui] rated insulation voltage | 250 V 2)IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 2.5 kV IEC 60947-1 | Electrical durability | 50000 cycles, DC-12, 1 A 30 V IEC 60947-5-1 appendix C<br />50000 cycles, AC-12, 0.5 A 125 V IEC 60947-5-1 appendix C<br />50000 cycles, AC-12, 0.5 A 250 V IEC 60947-5-1 appendix C |
| Electrical reliability | Λ = 10exp(-8) 5 V 1 mA with confidence level of 90 % IEC 60947-5-4 | Signalling type | Steady |
| current consumption | 20 mA | Service life | 50000 h |
| Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) | Ambient Air Temperature for Operation | 14…131 °F (-10…55 °C) |
| IP degree of protection | IP65 IEC 60529 | Standards | JIS C 4520<br />CSA C22.2 No 14<br />IEC 60947-1<br />UL 508<br />JIS C 852<br />IEC 60947-5-1 |
| Product Certifications | cURus<br />CCC | Vibration resistance | 1 mm 5…55 Hz)IEC 60068-2-6<br />9 gn 5…55 Hz)IEC 60068-2-6 |
| Shock resistance | 20 gn 11 ms) half sine wave acceleration IEC 60068-2-27 | Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 8 kV conforming to IEC 61000-4-2 |
Specifications may be subject to change without notice