ZB4BVB1TQ
Product ID:24109
Updated: 2026/4/3

Key Features
- 1Provide clear visibility in industrial settings with high-brightness LED light. 2、Withstand harsh environments for reliable performance in demanding conditions. 3、Feature screw clamp terminals for simple and secure panel mounting. 4、Ensure compatibility with the Harmony XB4 series of modular units. 5、Consume only 18mA at 24V AC/DC for energy efficiency.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | Harmony XB4 | Product or Component Type | Complete body/light block assembly |
| Device short name | ZB4 | Fixing collar material | Zamak |
| Sale per indivisible quantity | 100 | Connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end |
| Light source | Protected LED | Bulb base | Integral LED |
| Light source colour | White | [Us] rated supply voltage | 24 V AC/DC 50/60 Hz |
| CAD overall width | 1.2 in (30 mm) | CAD overall height | 1.9 in (47 mm) |
| CAD overall depth | 1.5 in (37 mm) | Terminals description ISO n°1 | (X1-X2)PL |
| Tightening torque | 7.08…10.6 lbf.in (0.8…1.2 N.m) EN 60947-1 | Shape of screw head | Cross Philips no 1<br />Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm |
| [Ui] rated insulation voltage | 600 V 3)EN 60947-1 | [Uimp] rated impulse withstand voltage | 6 kV EN 60947-1 |
| Signalling type | Steady | Supply voltage limits | 19.2…30 V DC<br />21.6…26.4 V AC |
| current consumption | 18 mA | Service life | 100000 h at rated voltage and 25 °C |
| Surge withstand | 1 kV IEC 61000-4-5 | Protective treatment | TH |
| Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) | Ambient Air Temperature for Operation | -40…158 °F (-40…70 °C) |
| Electrical shock protection class | Class I IEC 60536 | Standards | EN/IEC 60947-5-1<br />EN/IEC 60947-1<br />CSA C22.2 No 14<br />UL 508<br />JIS C8201-5-1<br />EN/IEC 60947-5-5<br />EN/IEC 60947-5-4<br />JIS C8201-1 |
| Product Certifications | CSA<br />UL Listed<br />GL<br />LROS (Lloyds register of shipping)<br />DNV<br />BV | Vibration resistance | 5 gn 2…500 Hz)IEC 60068-2-6 |
| Shock resistance | 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27 | Resistance to fast transients | 2 kV IEC 61000-4-4 |
| Resistance to electromagnetic fields | 9.1 V/m (10 V/m) IEC 61000-4-3 | Resistance to electrostatic discharge | 6 kV on contact (on metal parts) IEC 61000-2-6<br />8 kV in free air (in insulating parts) IEC 61000-2-6 |
| Electromagnetic emission | Class B IEC 55011 |
Specifications may be subject to change without notice