schneider ZB4BZ1056

Key Features

  • 1Withstand harsh industrial environments with IP5x protection. 2、Install easily with 1 x 0.250" or 2 x 0.110" connectors. 3、Suit various applications including electrical blocks. 4、Conform to IEC standards for shock and dust resistance. 5、Deliver 100,000 hours of service life at nominal voltage.
Product Details
ZB4BZ1056
schneider

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
Harmony XB4
Product or Component Type
Complete body/contact assembly
Device short name
ZB4
Fixing collar material
Zamak
Sale per indivisible quantity
1
Contacts type and composition
1 NO/1 NC
Contact operation
Slow-break
Contact block type
Single
Device Composition
Contact block<br />Fixing collar
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end EN 60947-1<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end EN 60947-1
CAD overall width
1.2 in (30 mm)
CAD overall height
1.9 in (47 mm)
CAD overall depth
1.5 in (37 mm)
Terminals description ISO n°1
(11-12)NC<br />(11-12)NO
Net Weight
0.141 lb(US) (0.064 kg)
Contacts usage
Standard contacts
Positive opening
With EN/IEC 60947-5-1 appendix K
Operating travel
0.06 in (1.5 mm) NC changing electrical state)<br />0.1 in (2.6 mm) NO changing electrical state)<br />0.2 in (4.3 mm) total travel)
Operating torque
0.44 lbf.in (0.05 N.m) NO changing electrical state
Mechanical durability
5000000 cycles
Contacts material
Gold flashed (Ag/Ni/Au) contacts
Short-circuit protection
4 A cartridge fuse gG EN/IEC 60947-5-1
[Ith] conventional free air thermal current
10 A EN/IEC 60947-5-1
[Ui] rated insulation voltage
250 V 3)EN 60947-1
[Uimp] rated impulse withstand voltage
4 kV EN 60947-1
[Ie] rated operational current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1<br />6 A 120 V, AC-15, A300 EN/IEC 60947-5-1<br />0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1<br />0.22 A 125 V, DC-13, R300 EN/IEC 60947-5-1
Electrical durability
1000000 cycles, AC-15, 1 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 1.5 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 3 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.15 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Electrical reliability
Λ < 10exp(-6) 5 V, 1 mA in clean environment EN/IEC 60947-5-4<br />Λ < 10exp(-8) 17 V, 5 mA in clean environment EN/IEC 60947-5-4
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-13…158 °F (-25…70 °C)
IP degree of protection
IP20 IEC 60529
Standards
UL 508<br />EN/IEC 60947-5-4<br />EN/IEC 60947-1<br />JIS C8201-5-1<br />CSA C22.2 No 14<br />EN/IEC 60947-5-1<br />EN/IEC 60947-5-5<br />JIS C8201-1
Product Certifications
DNV<br />LROS (Lloyds register of shipping)<br />BV<br />CSA<br />UL<br />GL
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice