ZB5AG710
Product ID:25318
Updated: 2026/4/6

Key Features
- 1Control machines with a secure keyed interface. 2、Resist impact, dust, water, and vibration with IP66 rating. 3、Install and replace quickly on compatible units. 4、Switch securely between operating modes. 5、Ensure compatibility with Harmony XB5 and XB4 series.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | Harmony XB5 | Product or Component Type | Head for key selector switch |
| Device short name | ZB5 | Bezel material | Dark grey plastic |
| Mounting diameter | 0.9 in (22 mm) | Head type | Standard |
| Sale per indivisible quantity | 1 | Shape of signaling unit head | Round |
| Type of operator | To centre spring return | Operator profile | Black key switch |
| Operator position information | 3 positions +/- 45° | Type of Keylock | Key 458A |
| Key withdrawal position | Center | CAD overall width | 1.1 in (29 mm) |
| CAD overall height | 1.1 in (29 mm) | CAD overall depth | 2.8 in (72 mm) |
| Net Weight | 0.126 lb(US) (0.057 kg) | Mechanical durability | 1000000 cycles |
| Station name | XALD 1...5 cut-outs<br />XALK 2...5 cut-outs | Electrical composition code | C4 6 single and double front mounting<br />C5 5 single front mounting<br />C6 5 single and double front mounting<br />C7 4 single front mounting<br />C8 4 single and double front mounting<br />C11 3 single front mounting<br />C3 6 single front mounting<br />SF1 3 single front mounting<br />SR1 3 single rear mounting |
| Device presentation | Basic element | Protective treatment | TH |
| Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) | Ambient Air Temperature for Operation | -40…158 °F (-40…70 °C) |
| Overvoltage category | Class II IEC 60536 | IP degree of protection | IP66 IEC 60529<br />IP67<br />IP69<br />IP69K |
| NEMA degree of protection | NEMA 13<br />NEMA 4X | Resistance to high pressure washer | 1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m |
| IK degree of protection | IK06 conforming to IEC 50102 | Standards | UL 508<br />IEC 60947-5-4<br />JIS C8201-5-1<br />CSA C22.2 No 14<br />IEC 60947-5-1<br />IEC 60947-1<br />JIS C8201-1 |
| Product Certifications | DNV<br />CSA<br />BV<br />LROS (Lloyds register of shipping)<br />UL Listed | Vibration resistance | 5 gn 2…500 Hz)IEC 60068-2-6 |
| Shock resistance | 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27 |
Specifications may be subject to change without notice