Key Features
- 1Utilize a plastic fixing collar and silver alloy contacts for enhanced durability. 2、Incorporate a BA9s LED bulb to deliver clear white light visibility. 3、Ensure compliance with international IEC and UL safety standards. 4、Feature screw clamp terminals and an integral transformer for simplified installation. 5、Maintain compatibility with Harmony XB5 and XB4 system ranges.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | Harmony XB5 | Product or Component Type | Complete body/contact assembly and light block |
| Device short name | ZB5 | Fixing collar material | Plastic |
| Sale per indivisible quantity | 1 | Head type | Standard |
| Contacts type and composition | 1 NO + 1 NC | Contact operation | Slow-break |
| Connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end EN 60947-1<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end EN 60947-1 | Light source | LED |
| Bulb base | BA 9s | Light block supply | Via integral transformer 1.2 VA 6 V |
| Light source colour | White | CAD overall width | 1.2 in (30 mm) |
| CAD overall height | 1.7 in (42 mm) | CAD overall depth | 3.1 in (79 mm) |
| Terminals description ISO n°1 | (11-12)NC<br />(13-14)NO | Net Weight | 0.262 lb(US) (0.119 kg) |
| Contacts usage | Standard | Positive opening | With EN/IEC 60947-5-1 appendix K |
| Operating travel | 0.06 in (1.5 mm) NC changing electrical state)<br />0.1 in (2.6 mm) NO changing electrical state)<br />0.2 in (4.3 mm) total travel) | Operating force | 2 N NC changing electrical state<br />2.3 N NO changing electrical state |
| Operating torque | 0.44 lbf.in (0.05 N.m) NO changing electrical state | Mechanical durability | 5000000 cycles |
| Tightening torque | 7.08…10.6 lbf.in (0.8…1.2 N.m) EN 60947-1 | Shape of screw head | Cross Philips no 1<br />Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm |
| Contacts material | Silver alloy (Ag/Ni) | Short-circuit protection | 10 A cartridge fuse gG EN/IEC 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A EN/IEC 60947-5-1 | [Ui] rated insulation voltage | 600 V 3)EN 60947-1 |
| [Uimp] rated impulse withstand voltage | 6 kV EN 60947-1 | [Ie] rated operational current | 3 A 240 V, AC-15, A600 EN/IEC 60947-5-1<br />6 A 120 V, AC-15, A600 EN/IEC 60947-5-1<br />0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1<br />1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1 |
| Electrical durability | 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C | Electrical reliability | Λ < 10exp(-6) 5 V 1 mA in clean environment EN/IEC 60947-5-4<br />Λ < 10exp(-8) 17 V 5 mA in clean environment EN/IEC 60947-5-4 |
| Signalling type | Steady | [Us] rated supply voltage | 400 V AC 50/60 Hz |
| Protective treatment | TH | Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
| Ambient Air Temperature for Operation | -40…158 °F (-40…70 °C) | Electrical shock protection class | Class II IEC 60536 |
| Standards | JIS C8201-5-1<br />EN/IEC 60947-1<br />UL 508<br />EN/IEC 60947-5-1<br />EN/IEC 60947-5-4<br />CSA C22.2 No 14<br />JIS C8201-1 | Product Certifications | GL<br />UL Listed<br />DNV<br />CSA<br />BV<br />LROS (Lloyds register of shipping) |
| Vibration resistance | 5 gn 2…500 Hz)IEC 60068-2-6 | Shock resistance | 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27 |
Specifications may be subject to change without notice