schneider ZB5AW14C1

Key Features

  • 1Withstand harsh conditions with robust IP66 protection. 2、Ensure clear visibility using red illuminated signaling. 3、Achieve over 10 million cycles for high mechanical durability. 4、Optimize panel space with a compact 22mm mounting size. 5、Simplify operation via an extended projecting spring return.
Product Details
ZB5AW14C1
schneider

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
Harmony XB5
Product or Component Type
Head for illuminated push-button
Device short name
ZB5
Product Compatibility
BA 9s
Bezel material
Plastic colour plated white
Mounting diameter
0.9 in (22 mm)
Sale per indivisible quantity
1
Head type
Standard
Shape of signaling unit head
Round
Type of operator
spring return
Operator profile
Red projecting, unmarked
Operator additional information
With plain lens
CAD overall width
1.1 in (29 mm)
CAD overall height
1.1 in (29 mm)
CAD overall depth
1.3 in (32 mm)
Net Weight
0.037 lb(US) (0.017 kg)
Resistance to high pressure washer
1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m
Mechanical durability
10000000 cycles
Station name
XALD 1...5 cut-outs<br />XALK 2...5 cut-outs
Cap/operator or lens colour
Red
Marking
Unmarked
Electrical composition code
M7 6 single front mounting BA 9s<br />M8 6 single and double front mounting BA 9s<br />M9 2 single front mounting BA 9s and transformer<br />MF2 2 single front mounting BA 9s
Device presentation
Basic sub-assemblies
Protective treatment
TC
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-40…131 °F (-40…55 °C)
Overvoltage category
Class II IEC 60536
IP degree of protection
IP66 IEC 60529
NEMA degree of protection
NEMA 13<br />NEMA 4X
IK degree of protection
IK05 conforming to EN 50102
Standards
UL 508<br />EN/IEC 60947-5-1<br />EN/IEC 60947-5-4<br />JIS C8201-5-1<br />CSA C22.2 No 14<br />GB 14048.5<br />EN/IEC 60947-1<br />JIS C8201-1
Product Certifications
BV<br />UL Listed<br />LROS (Lloyds register of shipping)<br />GL<br />CSA<br />DNV
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice