ZB6E2D
Product ID:26901
Updated: 2026/4/8

Key Features
- 1Choose high-quality plastic construction for durable, long-lasting performance. 2、Select 2-Position or 3-Position configurations to meet various control needs. 3、Install the compact 16 mm design in restricted surface area applications. 4、Ensure safety with RoHS, UL 508, and CSA C22.2 No. compliance. 5、Apply this versatile switch to control boards, surveillance rooms, and alarms.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | Harmony XB6 | Product or Component Type | Contact block |
| Device short name | ZB6 | Sale per indivisible quantity | 10 |
| Contacts type and composition | 1 NC | Contact operation | Slow-break |
| Contact block type | Single | Connections - terminals | Pins for printed circuit board |
| Contacts material | Gold flashed (Ag/Ni/Au) contacts | Terminals description ISO n°1 | (1-2)NC |
| Net Weight | 0.009 lb(US) (0.004 kg) | Positive opening | With EN/IEC 60947-5-1 appendix K |
| Operating travel | 0.04 in (1 mm) NC changing electrical state)<br />0.1 in (3.5 mm) total travel) | Operating force | 2.5 N NC changing electrical state |
| Mechanical durability | 5000000 cycles | Short-circuit protection | 6 A cartridge fuse gG |
| [Ui] rated insulation voltage | 250 V 3)EN/IEC 60947-1 | [Uimp] rated impulse withstand voltage | 4 kV EN/IEC 60947-1 |
| [Ie] rated operational current | 3 A 120 V, AC-15, B300<br />1.5 A 240 V, AC-15, B300<br />0.1 A 250 V, DC-13, R300<br />0.22 A 125 V, DC-13, R300 | Electrical durability | 1000000 cycles, AC-15 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C |
| Electrical reliability | Λ = 10exp(-8) 5 V 1 mA with confidence level of 90 % EN/IEC 60947-5-4 | Protective treatment | TC |
| Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) | Ambient Air Temperature for Operation | -13…158 °F (-25…70 °C) |
| IP degree of protection | IP20 IEC 60529 | Standards | UL 508<br />JIS C 4520<br />EN/IEC 60947-5-4<br />JIS C 852<br />EN/IEC 60947-1<br />CSA C22.2 No 14<br />EN/IEC 60947-5-1 |
| Product Certifications | CCC<br />CSA<br />UL<br />GOST | Vibration resistance | +/- 3 mm 2…500 Hz)IEC 60068-2-6<br />5 gn 2…500 Hz)IEC 60068-2-6 |
| Shock resistance | 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27 |