schneider ZBE1016TQ

Key Features

  • 1Achieve fast and easy assembly and disassembly. 2、Withstand harsh industrial environments with robust construction. 3、Ensure reliable switching with durable silver alloy contacts. 4、Connect versatilely using compatible screw clamp terminals. 5、Deploy in high-reliability industrial applications confidently.
Product Details
ZBE1016TQ
schneider

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
Harmony XB5<br />Harmony XB4
Product or Component Type
Contact block
Device short name
ZBE
Sale per indivisible quantity
100
IP degree of protection
IP20 IEC 60529
Contact operation
Slow-break
Contact block type
Single
Contacts usage
Low power switching contacts
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end EN 60947-1<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end EN 60947-1
Contacts type and composition
1 NO
Positive opening
Without
Operating travel
0.1 in (2.6 mm) NO changing electrical state)<br />0.2 in (4.3 mm) total travel)
Operating force
2.3 N NO changing electrical state
Mechanical durability
10000000 cycles
Tightening torque
7.08…10.6 lbf.in (0.8…1.2 N.m) EN 60947-1
Shape of screw head
Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm
Contacts material
Gold flashed (Ag/Ni/Au) contacts
Short-circuit protection
10 A cartridge fuse gG EN/IEC 60947-5-1
[Ith] conventional free air thermal current
10 A EN/IEC 60947-5-1
[Ui] rated insulation voltage
600 V 3)EN 60947-1
[Uimp] rated impulse withstand voltage
6 kV EN 60947-1
[Ie] rated operational current
3 A 240 V, AC-15, A600 EN/IEC 60947-5-1<br />6 A 120 V, AC-15, A600 EN/IEC 60947-5-1<br />0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1<br />1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1
Electrical durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Mounting of block
Front mounting
Electrical composition code
C1 9)<br />C2 7)<br />C3 6)<br />C4 4)<br />C5 5)<br />C6 3)<br />C7 4)<br />C8 2)<br />C9 3)<br />C12 6)<br />M1 6)<br />M2 4)<br />M3 4)<br />M5 2)<br />M6 2)<br />M7 6)<br />M8 4)<br />M9 2)<br />SF1 3)<br />SF2 2)<br />MF1 2)<br />MF2 2)<br />C10 2)<br />M4 2)<br />C13 1)
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-40…158 °F (-40…70 °C)
Standards
EN/IEC 60947-5-1<br />CSA C22.2 No 14<br />JIS C8201-5-1<br />UL 508<br />EN/IEC 60947-5-4<br />EN/IEC 60947-1<br />JIS C8201-1
Product Certifications
UL<br />DNV<br />GOST<br />BV<br />CCC<br />GL<br />CSA<br />LROS (Lloyds register of shipping)
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice