| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | Harmony XB4<br />Harmony XB5 | Product or Component Type | Light block |
| Device short name | ZBW | Connections - terminals | Screw terminals for lug |
| Signalling type | Steady | Light source | LED |
| Bulb base | BA 9s | Light block supply | Integrated transformer 6 V |
| Light source colour | White | [Us] rated supply voltage | 400 V AC 50 Hz |
| Service life | 100000 h at rated voltage and 25 °C | Surge withstand | 1 kV IEC 61000-4-5 |
| Protective treatment | TH | Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
| Ambient Air Temperature for Operation | -13…158 °F (-25…70 °C) | IP degree of protection | IP20 IEC 60529 |
| Standards | EN/IEC 60947-5-1<br />JIS C8201-5-1<br />UL 508<br />CSA C22.2 No 14<br />EN/IEC 60947-1<br />EN/IEC 60947-5-4<br />EN/IEC 60947-5-5<br />JIS C8201-1 | Resistance to fast transients | 2 kV IEC 61000-4-4 |
| Resistance to electromagnetic fields | 9.1 V/m (10 V/m) IEC 61000-4-3 | Resistance to electrostatic discharge | 6 kV on contact (on metal parts) IEC 61000-4-2<br />8 kV in free air (in insulating parts) IEC 61000-4-2 |
| Electromagnetic emission | Class B IEC 55011 |